环能瓦斯发电机组机房的消防的注意事项有哪些?

发布时间:2026-01-22 发布人:中拓 发布来源:http://www.zhongtuopower.cn/

  环能瓦斯发电机组一般放在机房里,机房可布置在高层建筑、机房的首层或地下室。机房的设置有很多的事项需要注意。下面带你们看一下环能瓦斯发电机组组机房的消防注意事项是怎样的。

  The environmental energy gas generator set is generally placed in the computer room, which can be arranged in high-rise buildings, the first floor of the computer room, or the basement. There are many things to pay attention to when setting up a computer room. Next, let me show you the fire safety precautions for the environmental energy gas generator unit room.

base64_image

  1、环能瓦斯发电机组房应采用耐火极限不低于2.00h的隔墙和1.5h的楼板与其他部位隔开。

  1. The environmental energy gas generator room should be separated from other parts by partition walls with a fire resistance limit of not less than 2.00 hours and floor slabs with a fire resistance limit of 1.5 hours.

  2、高层建筑内,环能瓦斯发电机组房内应设置储油间,其总储油量不应超过8.00h的需要量,或日用油箱容积不大于1m3。储油间应采用防火墙与发电机间隔开;当必须在防火墙上开门时,应设置能自行关闭的甲级防火门。

  2. In high-rise buildings, an oil storage room should be installed in the environmental energy gas generator unit room, with a total oil storage capacity not exceeding the required amount for 8.00 hours, or a daily fuel tank capacity not exceeding 1m3. The oil storage room should be separated from the generator by a firewall; When it is necessary to open the door on the firewall, a Class A fire door that can be closed by itself should be installed.

  3、环能瓦斯发电机组房布置在非高层建筑物内时,环能瓦斯发电机组房及日用油箱间耐火等级为一级。

  3. When the environmental energy gas generator unit room is arranged in a non high-rise building, the fire resistance rating between the environmental energy gas generator unit room and the daily fuel tank room is level one.

  4、应设置火灾自动报警系统和自动灭火系统。

  4. Automatic fire alarm system and automatic fire extinguishing system should be installed.

  5、环能瓦斯发电机组房和控制间的照明支线应接在消防配电的回路上。

  5. The lighting branch lines of the environmental energy gas generator unit room and control room should be connected to the fire power distribution circuit.

  6、机房内必须配备消防器材。

  6. Firefighting equipment must be equipped in the computer room.

  地面一层的公共建筑之中计划建一个环能瓦斯发电机组组室,请问有哪些消防规定规范?

  What are the fire safety regulations and standards for building an environmental energy gas generator unit room in a public building on the ground floor?

  (1)机房外设有消防栓、消防带、消防设施。

  (1) The computer room is equipped with fire hydrants, fire hoses, and fire-fighting facilities.

  (2)机房内设有油类灭火器干粉灭火器和气体灭火器。

  (2) There are oil fire extinguishers, dry powder fire extinguishers, and gas fire extinguishers in the computer room.

  (2)设有醒目严禁烟火全安图标、和禁止烟火文字。

  (2) There are prominent safety icons prohibiting smoking and fireworks, as well as text prohibiting smoking and fireworks.

  (3)机房内设有干燥沙池。

  (3) There is a dry sand pit in the computer room.

  (4)与油库要有隔离措施。

  (4) Isolation measures should be taken from the oil depot.

  1、可布置在建筑物的首层或地下一、二层,不应布置在地下三层及以下。柴油的闪点不应小于55℃。

  1. It can be arranged on the first floor or the first or second basement level of a building, and should not be arranged on the third basement level or below. The flash point of diesel should not be less than 55 ℃.

  2、环能瓦斯发电机组房应根据防火等级选择耐火2.00h的隔墙和1.50h的楼板与其他部位隔开。

  2. The environmental energy gas generator room should be separated from other parts by a 2.00-hour fire-resistant partition wall and a 1.50-hour floor slab according to the fire rating.

  3、应单独设置储油间,储油量不超过8小时需要量,采取防泄、露油措施,油箱应由通气管(室外),储油间应采用防火墙与发电机间隔开;当必须在防火墙上开门时,应设置能自行关闭的甲级防火门,设置火灾报警装置,设置灭火设施:如气体、泡沫、水喷雾等自动灭火设施(灭油火)。

  3. A separate oil storage room should be set up, with a storage capacity not exceeding the required amount for 8 hours. Measures should be taken to prevent leakage and oil leakage. The oil tank should be equipped with a vent pipe (outdoor), and the oil storage room should be separated from the generator by a firewall; When the door must be opened on the firewall, it shall be equipped with Class A fire doors that can be closed automatically, fire alarm devices and fire extinguishing facilities: such as gas, foam, water spray and other automatic fire extinguishing facilities (oil fire extinguishing).

  在选择机房位置时应注意以下几点:

  When choosing the location of the computer room, the following points should be noted:

  ①尽量靠近变配电所,这样便于接线、缩短线缆长度、减少电能损耗。

  ① Try to be as close to the substation as possible to facilitate wiring, shorten cable length, and reduce energy loss.

  ②设置在地下一层时,尽量要有一面靠外墙,以便通风、排烟。

  ② When located on the basement level, try to have one side facing the exterior wall for ventilation and smoke exhaust.

  ③应注意机组的吊装、搬运和检修方便。一般利用停车库出入通道作为搬运通道,但若通道不能满足要求,要考虑预留吊装孔。

  ③ Attention should be paid to the convenience of lifting, handling, and maintenance of the unit. Generally, the parking garage access channel is used as a handling channel, but if the channel cannot meet the requirements, it is necessary to consider reserving lifting holes.

  消防实施的配置:

  Configuration of fire protection implementation:

  1、机房内必须设置有油类灭火器干粉灭火器和气体灭火器。

  1. Oil fire extinguishers, dry powder fire extinguishers, and gas fire extinguishers must be installed in the computer room.

  2、机房外设置有消防栓和消防水带跟消防设施。

  2. Fire hydrants, fire hoses, and fire-fighting facilities are installed outside the computer room.

  3、并且在机房周围设置醒目严禁烟火图标和禁止烟火文字。

  3. And set up prominent no smoking icons and no smoking text around the computer room.

  4、机房内部设置有干燥的消防沙。

  4. Dry fire sand is installed inside the computer room.

  5、与油房要有隔离设施。

  5. There should be isolation facilities in the oil room.

  6、发电机组应当距离建筑物和其他设备至少1米,冰保持良好的通风。

  6. The generator set should be at least 1 meter away from buildings and other equipment, and the ice should be well ventilated.

  7、在机房内部有应急照明、应急指示,如果是地下室还要有独立的抽风系统,火警装置。

  7. There are emergency lighting and emergency instructions inside the computer room. If it is a basement, there should also be an independent ventilation system and fire alarm device.